Skip to content
NuSep logo

NuSep

Innovative Protein Discovery

  • Home
  • NuSep
    • Our Stories
    • nUView Technology
    • Join Us
  • Markets
    • nUView for Research
      • Western Blot
      • Protein Purification
      • LC-MS
    • nUView for Biopharma
      • Bioprocessing Monitoring
      • Impurity Testing
    • nUView for Education
  • Products
    • Precast Gels
    • Buffers & Reagents
      • Running Buffers
      • SingleShot Buffers
    • Blotting Membranes
      • Nitrocellulose Membranes
      • PVDF Membranes
      • Blotting Paper
    • Apparatus
      • Power Supply
      • Mini-Imager
      • Gel Tank
      • UV Transilluminator
    • Consumables
      • Sterile Syringe Filter
      • Empty Gel Cassettes
      • Proteus Columns
      • MiniSpin Columns
      • Snap Spin Columns
      • Gel Loading Tips
  • Support
    • Support Center
    • Forum
    • NuSep Publication List
  • Contact Us
    • Contact Us
    • Distributors

Sterile Syringe Filter

  • Home
  • Products
  • Sterile Syringe Filter

Products

  • Precast Gels
  • Buffers & Reagents
    • Running Buffers
    • SingleShot Buffers
  • Membranes & Blotting Papers
    • Nitrocellulose Membranes
    • PVDF Membranes
    • Blotting Paper
  • Apparatus
    • Power Supply
    • Mini-Imager
    • Gel Tank
    • UV Transilluminator
  • Consumables
    • Sterile Syringe Filter
    • Empty Gel Cassettes
    • FPLC Columns
    • MiniSpin Columns
    • Snap Spin Columns
    • Gel Loading Tips
  • Shop All

Sterile Syringe Filter

Sterile Syringe Filter - yellow and green
Order Now
Description
Specifications
Uses
Ordering
Description

The disposable syringe filter is a fast, convenient and reliable filter tool commonly used in laboratories. It has a simple, elegant design and is easy to clean. Its design eliminates the need for changing membranes and cleaning filters, helping you save time from complicated preparation procedures. It is often used in the laboratory, especially for pre-filtration, clarification, and sterilization filtration of particles, liquids and gases. It is the preferred method for filtering small samples of HPLC and GC, and is often used with disposable syringes. The filtration diameter is 4 mm to 50 mm, and the treatment amount is between 0.5 ml and 200 ml.         

The consistency in quality of the disposable needle filter is reliable due to strict quality control standards. There are strict control processes in place to ensure quality, from raw materials to production to delivery. 

Common membranes are available in various styles: polyethersulfone (PES) / polytetrafluoroethylene (PTFE) / nylon/ mixed cellulose (MCE) / glass fiber membrane (GF) / polyvinylidene fluoride (PVDF) / cellulose acetate (CA), etc.; pore size ranging from 0.1 μm to 5 μm; diameter 4 mm / 13 mm / 17 mm / 25 mm / 30 mm / 47 mm.

Specifications

Filter Material

Performance

Nylon

Resistant to strong alkalis and organic liquids
Natural hydrophilicity
No need to infiltrate before use
Uniform aperture mechanical strength
Threaded interface design

Mixed Cellulose (MCE)

High porosity and good interception effect
Not resistant to strong acids, strong alkali solutions and most organic solvents
Ideal for filtration of aqueous water solutions
Unique threaded interface design

Cellulose (CA)

Natural hydrophilicity
Low protein adhesion
No nitrates
Suitable for aqueous solution treatment and filtration of groundwater
Uniform pore structure
Extensive pore size selection
Retention of granulosa cells

Polyethersulfone (PES)

High solvent recovery rate
Low residual amount
High throughput
High microbial filtration capacity
Unique threaded interface design
Low protein adsorption
Low dissolution

Polyvinylidene Flouride (PVDF)

Hydrophobic film
No moisture absorption
Easy to maintain weight
Temperature resistant with repeated hot pressing
Chemical resistant
Oxidation resistant
Threaded interface design

Polytetrafluoroethylene (PTFE)

Excellent chemical resistance
High temperature resistance
Strong acid resistance
Strong alkali
Hydrophobic  

Have both hydrophilic and hydrophobic membranes available to meet different liquid filtration needs

Glass Fiber (GF)

 Natural hydrophobicity  
Large flux and pollution  
Good mechanical strength

Uses
  1. Removal of protein precipitates and dissolution assay
  2. Beverage food testing analysis and biofuel analysis
  3. Sample preparation
  4. Environmental monitoring and analysis
  5. Analysis of pharmaceutical and original liquid products
  6. Liquid Chromatography Sample Preparation and Specific QC Analysis
  7. Gas filtration and fluid detection
Ordering
Filter MaterialsDiameter (mm)Pore (µM)Pc/bag
CA(Cellulose Acetate)130.2210
CA(Cellulose Acetate)130.4510
CA(Cellulose Acetate)170.2210
CA(Cellulose Acetate)170.4510
CA(Cellulose Acetate)250.2210
CA(Cellulose Acetate)250.4510
CA(Cellulose Acetate)330.2210
CA(Cellulose Acetate)330.4510
MCE(Mixed Cellulose)130.2210
MCE(Mixed Cellulose)130.4510
MCE(Mixed Cellulose)170.2210
MCE(Mixed Cellulose)170.4510
MCE(Mixed Cellulose)250.2210
MCE(Mixed Cellulose)250.4510
MCE(Mixed Cellulose)330.2210
MCE(Mixed Cellulose)330.4510
PES(Polyethersulfone)130.2210
PES(Polyethersulfone)130.4510
PES(Polyethersulfone)170.2210
PES(Polyethersulfone)170.4510
PES(Polyethersulfone)250.2210
PES(Polyethersulfone)250.4510
PES(Polyethersulfone)330.2210
PES(Polyethersulfone)330.4510
PTFE(Hydrophilic Polytetrafluoroethylene)130.2210
PTFE(Hydrophilic Polytetrafluoroethylene)130.4510
PTFE(Hydrophilic Polytetrafluoroethylene)170.2210
PTFE(Hydrophilic Polytetrafluoroethylene)170.4510
PTFE(Hydrophilic Polytetrafluoroethylene)250.2210
PTFE(Hydrophilic Polytetrafluoroethylene)250.4510
PTFE(Hydrophilic Polytetrafluoroethylene)330.2210
PTFE(Hydrophilic Polytetrafluoroethylene)330.4510
PTFE(Hydrophobic Polytetrafluoroethylene)130.2210
PTFE(Hydrophobic Polytetrafluoroethylene)130.4510
PTFE(Hydrophobic Polytetrafluoroethylene)170.2210
PTFE(Hydrophobic Polytetrafluoroethylene)170.4510
PTFE(Hydrophobic Polytetrafluoroethylene)250.2210
PTFE(Hydrophobic Polytetrafluoroethylene)250.4510
PTFE(Hydrophobic Polytetrafluoroethylene)330.2210
PTFE(Hydrophobic Polytetrafluoroethylene)330.4510
PVDF(Hydrophilic PVDF)330.2210
PVDF(Hydrophilic PVDF)330.4510
PVDF(Hydrophilic PVDF)130.2210
PVDF(Hydrophilic PVDF)130.4510
PVDF(Hydrophilic PVDF)170.2210
PVDF(Hydrophilic PVDF)170.4510
PVDF(Hydrophilic PVDF)250.2210
PVDF(Hydrophilic PVDF)250.4510
PVDF(Hydrophobic PVDF)130.2210
PVDF(Hydrophobic PVDF)130.4510
PVDF(Hydrophobic PVDF)170.2210
PVDF(Hydrophobic PVDF)170.4510
PVDF(Hydrophobic PVDF)250.2210
PVDF(Hydrophobic PVDF)250.4510
PVDF(PVDF)330.2210
PVDF(PVDF)330.4510
 Nylon130.2210
 Nylon130.4510
 Nylon170.2210
 Nylon170.4510
 Nylon250.2210
 Nylon250.4510
 Nylon330.2210
 Nylon330.4510

 

Products

  • Precast Gels
  • Buffers & Reagents
    • Running Buffers
    • SingleShot Buffers
  • Membranes & Blotting Papers
    • Nitrocellulose Membranes
    • PVDF Membranes
    • Blotting Paper
  • Apparatus
    • Power Supply
    • Mini-Imager
    • Gel Tank
    • UV Transilluminator
  • Consumables
    • Sterile Syringe Filter
    • Empty Gel Cassettes
    • FPLC Columns
    • MiniSpin Columns
    • Snap Spin Columns
    • Gel Loading Tips
  • Shop All

Phone

Toll-Free: (877) 592-1060

Address

20271 Goldenrod Lane, Suite 2041
Germantown, MD 20876

Email

Technical Support: [email protected]

Membership and Sales: [email protected]

US Store
Products
NuSep Blog
Forum
Careers

Follow Us

  • Facebook
  • Twitter
  • LinkedIn
  • YouTube

Site Map

Terms and Conditions
Privacy Policy

NuSep Logo - white
©2025 NuSep, Inc. All rights reserved.
Cleantalk Pixel
 

Loading Comments...